Defibrillator
Calibration
Services

NABL-accredited calibration for all defibrillator types — AED, Manual, Energy Output Testers, and Cardioverters. IEC 60601-2-4 traceable, accepted by NABH, WHO GMP, and all hospital quality auditors.

1–360 J

Range

±5%

Accuracy

IEC 60601-2-4

Standard

IEC 60601-2-4

Defibrillator Standard

Defibrillator calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IEC 60601-2-4ISO/IEC 17025:20171–360 J Range±5% AccuracyNABH AcceptedWHO GMPOnsite Gujarat4 Defibrillator TypesNABL CC-2480IEC 60601-2-4ISO/IEC 17025:20171–360 J Range±5% AccuracyNABH AcceptedWHO GMPOnsite Gujarat4 Defibrillator Types
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS DEFIBRILLATOR CALIBRATION —

What Is Defibrillator Calibration & Why Does It Matter?

When a patient goes into ventricular fibrillation, every second counts — and the defibrillator must deliver exactly the energy the clinician selects. A unit that displays 200 J but delivers only 140 J may fail to restore normal rhythm. A unit that delivers 260 J may cause myocardial damage. Accuracy is literally life-or-death in this context.

Defibrillator calibration measures actual delivered energy at multiple levels using a calibrated 50Ω load analyser, verifies synchronisation mode performance, and checks charge time and battery capacity. The result is documented per IEC 60601-2-4 — a NABL certificate accepted by NABH, WHO GMP, and FDA auditors that proves your defibrillator is safe and accurate for clinical use.

Measure

Delivered energy measured at 5+ therapeutic levels using calibrated 50Ω load analyser.

Verify

Synchronisation delay, charge time, and pacing output verified against IEC 60601-2-4 limits.

Certify

NABL CC-2480 certificate issued — accepted by NABH, WHO GMP, and FDA biomedical auditors.

— INSTRUMENTS COVERED —

Defibrillator Types We Calibrate

AEDs, manual defibrillators, energy output testers, and cardioverters — all calibrated per IEC 60601-2-4.

01

AED Analyser

Automated external defibrillator analysers calibrated for energy output, charge time, and waveform accuracy.

1–360 JAcc: ±5%IEC 60601-2-4
02

Manual Defibrillator Analyser

Manual defibrillator performance testers verifying delivered energy, synchronisation, and pacing output.

1–360 JAcc: ±5%IEC 60601-2-4
03

Defibrillator Energy Output Tester

Standalone energy verification equipment for delivered joule accuracy across the full therapeutic range.

1–360 JAcc: ±5%IEC 60601-2-4
04

Cardioverter Verification

Synchronised cardioversion mode verification including R-wave detection accuracy and energy delivery confirmation.

1–360 JAcc: ±5%IEC 60601-2-4

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Safety Inspection

Defibrillator received and tagged. Physical inspection of paddles/pads, cables, battery condition, and display function. As-found status documented.

02

Battery & Charge Time Check

Battery capacity and charge time measured from depleted state. Charge time to maximum energy compared against manufacturer specification.

03

As-Found Energy Measurement

Delivered energy measured at 5+ levels (10, 50, 100, 200, 360 J) using calibrated defibrillator analyser into 50Ω test load. Deviations recorded.

04

Synchronisation Verification

R-wave synchronisation delay measured. Sync mode accuracy verified against ECG reference signal per IEC 60601-2-4.

05

As-Left Verification

Post-adjustment delivered energy re-measured at all calibration points. Expanded uncertainty calculated per ISO/IEC 17025.

06

NABL Certificate Issued

NABL CC-2480 certificate issued with delivered energy data, sync delay, battery status, and IEC 60601-2-4 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

Every defibrillator calibration follows IEC 60601-2-4 with full traceability to NPL national electrical standards. Our certificates satisfy NABH, WHO GMP, FDA, and all biomedical engineering audit requirements.

ISO/IEC 17025

NABL Accreditation Standard

IEC 60601-2-4

Defibrillator Standard

IEC 60601-1

Medical Equipment Safety

ISO 13485

Medical Device QMS

NABH

Hospital Accreditation

WHO GMP

GMP Compliance

NPL / NIST

Traceable Reference

ISO 9001:2015

Quality Management

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017, recognized under the ILAC MRA agreement. Our biomedical calibration certificates are valid for WHO GMP, FDA, NABH, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Defibrillator Calibration Also Available

For routine maintenance, bulk calibration, or facilities not needing NABL certification — Prism offers cost-effective non-NABL calibration with the same trained engineers and traceable references.

Internal maintenance & routine checks
Pre-delivery and incoming inspection
Bulk calibration for non-critical instruments
R&D and workshop environments
Cost-effective for projects without audit requirements

Traceable References

All non-NABL jobs use the same NPL-traceable references — only the certificate type differs.

Faster Turnaround

Non-NABL jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and as onsite service across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

NABL-certified engineers travel to your facility across Gujarat — hospital, pharma, or laboratory onsite service.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL biomedical certificate issued by Prism has been accepted by WHO GMP, FDA, NABH, and ISO auditors — no rejections, no rework.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, WHO GMP auditors internationally.
Fast Certificate Delivery
Same-day urgent service available. Certificates delivered digitally within 24 hours.
100% Onsite, No Downtime
Engineers travel to your facility. No instrument removal.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate WHO GMP & FDA accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Defibrillator Calibration Quote

Tell us what you need calibrated and whether you need onsite or in-lab service. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.