Infusion Pump
Calibration
Services

NABL-accredited calibration for infusion pump analysers, syringe pump testers, peristaltic pumps, and flow rate accuracy testers. IEC 60601-2-24 compliant. Accepted by NABH, WHO GMP, and FDA auditors across Gujarat.

IEC 60601-2-24Infusion Pump Standard
Range: 0.1–1200 mL/hrAccuracy: ±2%Standard: IEC 60601-2-24
NABL CC-2480IEC 60601-2-24ISO/IEC 17025:20170.1–1200 mL/hr±2% AccuracyNABH AcceptedWHO GMPOnsite Gujarat4 Pump Types
0+
Industries Served
0+
Instruments Calibrated
0+
Expert Engineers
0%
Repeat Client Rate

— WHAT IS IT —

What is Infusion Pump Calibration?

Infusion pump calibration is the process of verifying that an infusion pump tester or analyser accurately measures the flow rate, start-up bolus, and occlusion alarm pressure of IV infusion pumps and syringe drivers used in clinical settings.

IEC 60601-2-24 and NABH biomedical standards require documented periodic calibration of all infusion devices and test equipment used in ICUs, oncology, and neonatal care.

Prism's NABL CC-2480 calibration covers flow rate accuracy at 5+ settings, start-up bolus measurement, and occlusion alarm pressure verification across the full clinical delivery range.

Why Calibration Matters

Flow rate errors of ±10% can cause medication overdose or under-treatment
Start-up bolus can deliver dangerous peak doses at therapy initiation
IEC 60601-2-24 mandates documented flow rate verification
NABH SHCO requires annual calibration of all infusion devices
Occlusion alarm failures delay detection of blocked IV lines

— INSTRUMENTS COVERED —

Infusion Pump Equipment We Calibrate

01

IV Infusion Pump Analyser

Volumetric IV pump analysers measuring flow rate accuracy, occlusion alarm pressure, and bolus delivery accuracy.

0.1–1200 mL/hrRes: ±2%IEC 60601-2-24
02

Syringe Pump Tester

Syringe driver and syringe pump calibration for flow rate accuracy and start-up bolus at clinical delivery rates.

0.1–1200 mL/hrRes: ±2%IEC 60601-2-24
03

Peristaltic Pump Calibration

Peristaltic infusion pump flow rate calibration across the full delivery range using gravimetric or volumetric reference methods.

0.1–1200 mL/hrRes: ±2%IEC 60601-2-24
04

Flow Rate Accuracy Tester

Precision flow rate analysers calibrated for measuring infusion pump output accuracy at micro and macro delivery rates.

0.1–1200 mL/hrRes: ±2%IEC 60601-2-24

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Inspection

Infusion pump received and tagged. Physical inspection — pump mechanism, display, alarm function, and drug library status documented as-found.

02

Setup & Priming

IV set or syringe fitted and primed. Flow analyser connected to pump outlet. Reference conditions (room temperature, fluid type) documented.

03

Flow Rate Accuracy Test

Flow rate measured at 5+ settings across the clinical range using calibrated gravimetric or volumetric reference. Start-up bolus measured at each rate.

04

Occlusion Alarm Verification

Downstream occlusion alarm pressure threshold measured and compared against specification. KVO (keep vein open) rate verified.

05

As-Left Verification

Post-adjustment flow rate re-measured at all calibration points. Expanded uncertainty calculated per ISO/IEC 17025 and IEC 60601-2-24.

06

NABL Certificate Issued

NABL CC-2480 certificate with flow rate accuracy data, occlusion alarm results, start-up bolus, and IEC 60601-2-24 traceability.

— STANDARDS & COMPLIANCE —

Standards We Work To

ISO/IEC 17025
NABL Accreditation Standard
IEC 60601-2-24
Infusion Pump Standard
ISO 13485
Medical Device QMS
NABH
Hospital Accreditation
WHO GMP
GMP Compliance
FDA 21 CFR
US FDA Compliance
NPL / NIST
Traceable Reference
ISO 9001:2015
Quality Management

— NON-NABL OPTION —

Non-NABL Calibration Available

Not every calibration needs a NABL certificate. For internal quality checks, maintenance records, or large batch instruments, our non-NABL calibration service offers the same technical precision at a lower cost and faster turnaround.

All non-NABL calibrations use the same NPL-traceable reference standards and follow ISO/IEC 17025 methodology — only the certificate header differs.

Traceable References

All non-NABL jobs use the same NPL-traceable references — only the certificate type differs.

Faster Turnaround

Non-NABL jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and as onsite service across Gujarat — same team, same quality.

— SERVICE AREAS —

Onsite Calibration Across Gujarat

AhmedabadVadodaraBharuchDahejAnkleshwarSuratRajkotGandhinagarNadiadAnand

— WHY PRISM —

Why Choose Prism Calibration?

NABL CC-2480 — ILAC MRA

Accepted in 100+ countries. Recognized by FDA, GPCB, WHO GMP auditors internationally.

Fast Certificate Delivery

Same-day urgent service available. Certificates delivered digitally within 24 hours.

100% Onsite, No Downtime

Engineers travel to your facility. No instrument removal.

Triple Govt. Authorization

NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.

70+ Engineers

NABL-certified field & lab specialists

Same-Day Service

Urgent certificates when you need them

Zero Rejections

Every certificate WHO GMP & FDA accepted

All Gujarat

Every GIDC zone covered onsite

ILAC MRA

Globally recognized, 100+ countries

Since 2004

20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

— GET IN TOUCH —

Request a Calibration Quote

Fill in the form and our team will contact you within 2 business hours with pricing and availability for onsite or in-lab infusion pump calibration.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445
WhatsApp Us Now

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.