Digital Multimeter
(DMM)
Calibration

NABL-accredited calibration for handheld and bench digital multimeters. V, A, Ω — all functions verified per IEC 61010. Fluke, Keysight, Hioki, and all brands.

±0.005%

Accuracy

V, A, Ω

All Functions

IEC 61010

Standard

IEC 61010

Electrical Measuring Instruments

Digital multimeter DMM calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IEC 61010DC & AC VoltageDC & AC CurrentResistanceAll Brands5522A ReferenceISO 9001 AcceptedAll GujaratNABL CC-2480IEC 61010DC & AC VoltageDC & AC CurrentResistanceAll Brands5522A ReferenceISO 9001 AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS MULTIMETER CALIBRATION —

What Is Multimeter Calibration & Why Does It Matter?

Think of a quality lab that relies on a multimeter for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Multimeter calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Multimeters We Calibrate

Bench DMM / Handheld / True-RMS / Data Logger · All Makes · IEC 61010 · NABL accredited

01

Handheld Digital Multimeter

Portable handheld multimeters for voltage, current, and resistance measurement.

0–1000 V / 0–10 AAcc: ±0.5% FSIEC 61010
02

Bench Multimeter (6.5 digit)

High-precision 6.5-digit bench multimeters for laboratory calibration.

0–1000 V / 0–3 AAcc: ±0.005% FSIEC 61010
03

True RMS Multimeter

True RMS multimeters for accurate AC measurements of non-sinusoidal waveforms.

0–750 V AC True RMSAcc: ±0.5% FSIEC 61010
04

Auto-Ranging Multimeter

Auto-ranging multimeters with automatic range selection for faster measurements.

0–1000 V AC/DCAcc: ±0.5% FSIEC 61010
05

Industrial Multimeter (CAT III/IV)

Rugged industrial-grade multimeters rated CAT III/IV for high-energy environments.

0–1000 V CAT IVAcc: ±1.0% FSIEC 61010
06

Safety Multimeter (IEC 61010)

Safety-rated multimeters compliant with IEC 61010 for hazardous environments.

0–600 V CAT III/IVAcc: ±0.5% FSIEC 61010

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Function Inventory

DMM received. All active measurement functions (V DC, V AC, A DC, A AC, Ω, etc.) and ranges documented.

02

Reference Calibrator Setup

NABL-traceable Fluke 5522A or equivalent precision calibrator connected. Each DMM function tested per IEC 61010 calibration procedure.

03

Multi-Function Calibration

DC voltage, AC voltage, DC current, AC current, and resistance each calibrated at 5+ points per active range. All functions documented.

04

Continuity, Diode & Temperature (if fitted)

Additional functions (continuity, diode drop, thermocouple input) verified against traceable reference values.

05

Error & Uncertainty Calculation

Error at each calibration point. Expanded uncertainty (k=2) per GUM. Certificate lists every function tested.

06

NABL Certificate Issue

NABL CC-2480 multi-function certificate with all calibration data, uncertainty (k=2), IEC 61010 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IEC 61010-1

Electrical Measuring Instruments Safety

IEC 60051

Analogue Indicating Instruments

IEC 61557-2

Insulation Resistance Measurement

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. DMM multi-function calibration certificates accepted by ISO 9001, pharma, IATF 16949, and all industry QMS audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Multimeter Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Bulk multimeter calibration with 1-day turnaround. Gujarat-wide courier service.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL multimeter certificate from Prism has been accepted by ISO 9001, pharma, and all QMS audit bodies — no rejections.

NABL CC-2480 — ILAC MRA
ISO 9001, pharma, IATF 16949 auditors worldwide accept our certificates.
1-Day Bulk Turnaround
Large batches of plant DMMs calibrated in 1 business day.
Gujarat-Wide Courier
Insured pick-up and delivery from any Gujarat location.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified electrical specialists
1-Day Bulk Service
Large batches fast
Zero Rejections
Every certificate ISO & pharma accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of DMM calibration

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Multimeter Calibration Quote

Share the make/model, functions needed, and quantity. We respond within 2 business hours.