Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Universal
Calibrator
Calibration

NABL-accredited calibration for multi-function electrical calibrators (Fluke 5522A type). V DC/AC, I DC/AC, Ω, Hz, TC simulation, RTD simulation. All output functions. IEC 61010.

±0.003%

Accuracy

V/A/Ω/Hz/TC/RTD

Functions

IEC 61010

Standard

IEC 61010 · Fluke 5522A Type

All Output Functions Calibrated

Universal calibrator Fluke 5522A calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IEC 61010Fluke 5522AV/A/Ω/Hz/TC/RTDNPL TraceableIEC 60584IEC 60751ISO 9001 AcceptedAll GujaratNABL CC-2480IEC 61010Fluke 5522AV/A/Ω/Hz/TC/RTDNPL TraceableIEC 60584IEC 60751ISO 9001 AcceptedAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS UNIVERSAL CALIBRATOR CALIBRATION —

What Is Universal Calibrator Calibration & Why Does It Matter?

Think of a quality lab that relies on an universal calibrator for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Universal Calibrator calibrationmeans comparing its output against a NABL-traceable certified reference standard at multiple setpoints, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare output against a NABL-traceable reference standard across all functions and ranges.

Correct

Adjust or document deviations so output reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— FUNCTIONS CALIBRATED —

Universal Calibrator Output Functions

V DC/AC · I DC/AC · Resistance · Frequency · TC Simulation · RTD Simulation · IEC 61010 · NABL

01

Multifunction Process Calibrator

Multifunction calibrators for sourcing and measuring V, mA, TC, RTD, and frequency.

0–1000 V / 0–24 mA / TC/RTDAcc: ±0.01% FSIEC 61010
02

Universal Electrical Calibrator

Universal electrical calibrators for comprehensive electrical parameter calibration.

0–1000 V / 0–20 AAcc: ±0.02% FSIEC 61010
03

Voltage/Current Source Calibrator

Precision voltage and current source calibrators for transmitter calibration.

0–30 V / 0–24 mAAcc: ±0.02% FSIEC 61010
04

Precision DC Calibrator

High-accuracy DC voltage and current calibrators for bench laboratory use.

0–1100 V DC / 0–110 mA DCAcc: ±0.005% FSIEC 61010
05

Bench Calibrator

Bench-type calibrators for workbench calibration of electrical instruments.

0–1000 V / 0–20 AAcc: ±0.01% FSIEC 61010
06

Portable Universal Calibrator

Portable universal calibrators for field calibration of process instruments.

0–30 V / 0–24 mAAcc: ±0.02% FSIEC 61010

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Function Inventory

Universal calibrator received. All active output functions (V DC, V AC, I DC, I AC, Ω, Hz, TC types, RTD types) inventoried against calibration scope.

02

NABL Reference Source Setup

NABL-traceable primary measurement standards connected to measure/verify each calibrator output: precision voltmeter, ammeter, resistance standard, frequency counter, mV source.

03

Multi-Function Calibration

Each output function calibrated at 5 setpoints per range. DC and AC voltage, DC and AC current, resistance, frequency, TC mV, and RTD resistance all calibrated in sequence.

04

TC/RTD Simulation Accuracy

TC mV output at 5 temperature points per TC type compared to IEC 60584 mV table. RTD resistance at 5 points compared to IEC 60751 resistance table.

05

Error & Uncertainty Calculation

Error at each setpoint for all functions. Expanded uncertainty (k=2) per GUM. Certificate lists results for each function with traceability chain.

06

NABL Certificate Issue

NABL CC-2480 certificate listing all calibrated output functions with data, deviations, uncertainty (k=2), and IEC 61010 / IEC 60584 / IEC 60751 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IEC 61010-1

Safety for Measuring Instruments

IEC 60584

Thermocouples (TC Types J/K/T/E/N/R/S/B)

IEC 60751

Industrial PT100 RTD Standard

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Universal calibrator certificates accepted as top-level reference instruments by ISO 9001, pharma, IATF 16949, and all process industry QMS audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Universal Calibrator Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Courier pick-up and delivery. 1-day turnaround for most universal calibrators.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL universal calibrator certificate from Prism has been accepted by ISO 9001 and IATF 16949 auditors — no rejections.

NABL CC-2480 — ILAC MRA
ISO 9001, pharma, and IATF 16949 auditors accept our certificates.
1-Day Turnaround
Universal calibrators calibrated and certified in 1 business day.
Gujarat-Wide Courier
Insured pick-up and delivery from any Gujarat location.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified electrical specialists
1-Day Turnaround
Fast digital certificate delivery
Zero Rejections
Every certificate ISO accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of electrical metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Universal Calibrator Calibration Quote

Share the make/model and the output functions you need calibrated. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.