Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Compound Gauge
Calibration
Services

NABL-accredited calibration for Analog, Digital, Glycerine-Filled, Diaphragm Seal, Sanitary, and Standard Compound Gauges. ISO 5171 / ASME B40.100 traceable. Accepted by ISO 9001, GMP, IBR, PESO auditors.

±0.1% FS

Accuracy

–1 to +25 bar

Range

ISO 5171

Standard

ISO 5171

Compound Gauge Standard

Compound gauge calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 5171ASME B40.100IS 3624NPL Traceable–1 to +25 barVacuum & PressureOnsite GujaratNABL CC-2480ISO 5171ASME B40.100IS 3624NPL Traceable–1 to +25 barVacuum & PressureOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS COMPOUND GAUGE CALIBRATION —

What Is Compound Gauge Calibration & Why Does It Matter?

Think of a quality lab that relies on a compound gauge for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Compound Gauge calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Compound Gauges We Calibrate

All 6 types · All makes · –1 to +25 bar · NABL accredited

01

Analog Compound Pressure-Vacuum Gauge

Analog compound gauges measuring both vacuum and positive pressure.

-1 to 10 barAcc: ±1.6% FSEN 837-1
02

Digital Compound Gauge

Digital compound gauges with electronic sensing for vacuum and pressure.

-1 to 10 barAcc: ±0.1% FSEN 837-1
03

Glycerine-Filled Compound Gauge

Glycerine-filled compound gauges for vibration and pulsation dampening.

-1 to 10 barAcc: ±1.6% FSEN 837-1
04

Compound Gauge with Diaphragm Seal

Compound gauges with diaphragm seal for aggressive or viscous media.

-1 to 10 barAcc: ±1.6% FSEN 837-1
05

Sanitary Compound Gauge (3-A)

Sanitary 3-A certified compound gauges for food and pharmaceutical applications.

-1 to 10 barAcc: ±1.6% FS3-A / EN 837-1
06

Compound Gauge (–1 to 15 bar)

Standard compound gauges with –1 to 15 bar measuring range.

-1 to 15 barAcc: ±1.6% FSEN 837-1

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Tagging

Compound gauge received, tagged. Dual scale (vacuum and positive) range noted. Liquid fill type noted.

02

As-Found Measurement

Reference applies pressure/vacuum at 0%, 25%, 50%, 75%, 100% FS on both vacuum and positive sides. As-found readings logged.

03

Zero & Span Adjustment

Zero set at atmosphere. Vacuum side span and positive pressure side span both verified and adjusted.

04

Linearity & Hysteresis

Ascending and descending readings on both sides of the compound scale. Hysteresis calculated per ISO 5171.

05

As-Left Verification

Post-adjustment readings at 5 points on both sides confirm compliance. Expanded uncertainty (k=2) calculated.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty, ISO 5171 / ASME B40.100 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 5171

Pressure Gauges (General)

ASME B40.100

Pressure Gauges & Diaphragm Seals

IS 3624

Pressure & Vacuum Gauges (Indian)

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Compound gauge certificates accepted by ISO 9001, IATF 16949, GMP/FDA, IBR, PESO, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Compound Gauge Calibration Also Available

Routine maintenance calibration without NABL certification — same engineers, same dead weight tester, lower cost.

Routine HVAC and refrigeration gauge maintenance
Bulk calibration for utility compound gauges
Workshop gauges without audit need
Pre-delivery and incoming inspection
Cost-effective for non-critical systems

Dead Weight Tester Lab

All calibrations traceable to NPL via dead weight tester — only certificate type differs.

Faster Turnaround

Non-NABL compound gauge jobs faster — ideal for large bulk batches and routine maintenance.

Cost-Effective

Lower cost than NABL — right for utility compound gauges and HVAC maintenance.

Onsite or In-Lab

Portable reference to your plant across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

Onsite compound gauge calibration across Gujarat with portable dead weight testers.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL compound gauge certificate issued by Prism has been accepted by ISO, IATF, GMP, IBR, PESO, and GPCB auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours. Same-day for urgent plant shutdowns.
Onsite, No Downtime
Portable dead weight tester to your plant. No gauge removal, no production loss.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Compound Gauge Calibration Quote

Tell us the gauge type, range, quantity, and make. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.