Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Magnehelic Gauge
Calibration
Services

NABL-accredited calibration for Magnehelic DP, Low Range, High Range, Inclined-Vertical, Digital, and Filter DP Gauges. ISO 5171 / ASHRAE 52.2 traceable. Accepted by ISO 9001, GMP, ISO 14644 auditors.

±0.5% FS

Accuracy

0–50 kPa

Range

ISO 5171

Standard

ISO 5171

Magnehelic DP Standard

Magnehelic gauge calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 5171ASME B40.100ASHRAE 52.2NPL Traceable0–50 kPaCleanroom / HVACOnsite GujaratNABL CC-2480ISO 5171ASME B40.100ASHRAE 52.2NPL Traceable0–50 kPaCleanroom / HVACOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS MAGNEHELIC GAUGE CALIBRATION —

What Is Magnehelic Gauge Calibration & Why Does It Matter?

Think of a quality lab that relies on a magnehelic gauge for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Magnehelic Gauge calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Magnehelic Gauges We Calibrate

All 6 types · Dwyer and all makes · 0–50 kPa · NABL accredited

01

Magnehelic DP Gauge

Dwyer Magnehelic differential pressure gauges for HVAC and cleanroom applications.

0–25 Pa to 0–2500 PaAcc: ±2% FSISO 5167
02

Low Pressure Magnehelic (0–1 in WC)

Low-range Magnehelic gauges for very low DP measurement from 0–1 in WC.

0–1 in WC (0–250 Pa)Acc: ±2% FSISO 5167
03

High Range Magnehelic

High-range Magnehelic gauges for higher differential pressure applications.

0–10 in WC to 0–50 in WCAcc: ±2% FSISO 5167
04

Inclined-Vertical Manometer

Inclined-vertical manometers for low-pressure measurement with dual scale.

0–100 mmH₂OAcc: ±2% FSISO 5167
05

Digital Magnehelic Indicator

Digital Magnehelic indicators with electronic display and output options.

0–2500 PaAcc: ±1% FSISO 5167
06

Filter DP Indicator

Filter differential pressure indicators for air filter monitoring and replacement alerts.

0–500 PaAcc: ±2% FSISO 5167

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Tagging

Magnehelic gauge received, tagged. Range, make (Dwyer/equivalent), and mounting noted. Physical condition documented.

02

As-Found Measurement

Traceable low-pressure reference applies 0%, 25%, 50%, 75%, 100% FS to high port, low port vented to atmosphere. As-found readings recorded.

03

Zero Adjustment

Zero set with both ports equalized at atmosphere. Pointer/display aligned. Zero drift noted.

04

Linearity Verification

Ascending and descending 5-point readings. Linearity error and hysteresis calculated per ISO 5171.

05

As-Left Verification

Post-adjustment readings at 5 points confirm compliance. Expanded uncertainty (k=2) calculated. Pass/fail recorded.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty, ISO 5171 / ASHRAE 52.2 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 5171

Pressure Gauges (General)

ASME B40.100

Pressure Gauges & Diaphragm Seals

ASHRAE 52.2

HVAC Filter Test Standard

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Magnehelic gauge certificates accepted by ISO 9001, IATF 16949, GMP/FDA, ISO 14644 cleanroom, IBR, and PESO auditors.

— NON-NABL CALIBRATION —

Non-NABL Magnehelic Gauge Calibration Also Available

Routine maintenance calibration without NABL certification — same engineers, same low-pressure reference, lower cost.

Routine HVAC Magnehelic maintenance calibration
AHU/FCU filter DP gauge batch calibration
Workshop Magnehelic gauges without audit need
Pre-commissioning DP gauge calibration
Cost-effective for non-critical applications

Low Pressure Reference Lab

All calibrations traceable to NPL via low-pressure reference — only certificate type differs.

Faster Turnaround

Non-NABL Magnehelic jobs faster — ideal for large HVAC batch calibrations.

Cost-Effective

Lower cost than NABL — right for utility Magnehelic gauges and non-critical HVAC.

Onsite at Your Facility

Portable low-pressure reference to your plant — same team, same quality across Gujarat.

— AREAS WE SERVICE —

Serving All of Gujarat

Onsite Magnehelic gauge calibration across Gujarat with portable low-pressure references.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL Magnehelic certificate issued by Prism has been accepted by ISO, IATF, GMP, ISO 14644, IBR, PESO, and GPCB auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours. Same-day for urgent plant shutdowns.
Onsite, No Downtime
Portable low-pressure reference to your plant. No gauge removal, no production loss.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Magnehelic Gauge Calibration Quote

Tell us the gauge type, range, quantity, and make. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.