Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Vacuum Gauge
Calibration
Services

NABL-accredited calibration for Bourdon Tube Vacuum, Compound, Pirani, Thermocouple, and Capacitance Vacuum Gauges. ISO 3529 / ISO 5171 traceable. Accepted by ISO 9001, GMP, IBR, PESO auditors.

±0.1% FS

Accuracy

–1 to 0 bar

Range

ISO 3529

Standard

ISO 3529

Vacuum Technology Standard

Vacuum gauge calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 3529ISO 5171ASME B40.100NPL Traceable–1 to 0 barPirani / CapacitanceOnsite GujaratNABL CC-2480ISO 3529ISO 5171ASME B40.100NPL Traceable–1 to 0 barPirani / CapacitanceOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS VACUUM GAUGE CALIBRATION —

What Is Vacuum Gauge Calibration & Why Does It Matter?

Think of a quality lab that relies on a vacuum gauge for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Vacuum Gauge calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Vacuum Gauges We Calibrate

All 6 types · Bourdon to capacitance · –1 bar to 0.0001 mbar · NABL accredited

01

Bourdon Tube Vacuum Gauge

Bourdon tube vacuum gauges for negative pressure measurement in industrial systems.

-1 to 0 barAcc: ±1.0% FSEN 837-1
02

Digital Vacuum Gauge

Digital vacuum gauges with high-resolution electronic sensing.

-1 to 0 barAcc: ±0.1% FSEN 837-1
03

Compound Vacuum Gauge (–1 to 10 bar)

Compound gauges measuring both vacuum and positive pressure in one instrument.

-1 to 10 barAcc: ±1.0% FSEN 837-1
04

Pirani Vacuum Gauge

Pirani thermal conductivity vacuum gauges for medium vacuum measurement.

1 mbar to 1000 mbarAcc: ±5% FSISO 3567
05

Thermocouple Vacuum Gauge

Thermocouple vacuum gauges for vacuum measurement based on heat conductivity.

1 mbar to 1000 mbarAcc: ±10% FSISO 3567
06

Capacitance Manometer (Vacuum)

High-precision capacitance manometers for vacuum and low-pressure measurement.

0.001 mbar to 1000 mbarAcc: ±0.2% FSISO 3567

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Tagging

Vacuum gauge received, tagged. Range, type (Bourdon/Pirani/Capacitance) noted. Physical condition documented.

02

As-Found Measurement

Reference vacuum controller/dead weight tester applies 0%, 25%, 50%, 75%, 100% FS vacuum. As-found readings logged.

03

Zero & Span Adjustment

Zero at atmosphere (0 vacuum). Span set at calibrated vacuum reference. Pointer or display aligned.

04

Linearity Verification

Ascending and descending readings at 5 points. Hysteresis calculated. Pirani/thermocouple response verified.

05

As-Left Verification

Post-adjustment readings confirm compliance. Expanded uncertainty (k=2) calculated. Pass/fail recorded.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left vacuum readings, uncertainty, ISO 3529/ISO 5171 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 3529

Vacuum Technology Vocabulary

ISO 5171

Pressure Gauges (General)

ASME B40.100

Pressure & Vacuum Gauges

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Vacuum gauge certificates accepted by ISO 9001, IATF 16949, GMP/FDA, IBR, PESO, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Vacuum Gauge Calibration Also Available

Routine maintenance calibration without NABL certification — same engineers, same vacuum reference, lower cost.

Routine plant maintenance calibration
Vacuum drying oven and freeze dryer batch calibration
Utility vacuum gauge maintenance
Workshop gauges without audit need
Cost-effective for non-critical vacuum systems

Vacuum Reference Lab

All calibrations traceable to NPL via vacuum reference standards — only certificate type differs.

Faster Turnaround

Non-NABL vacuum gauge jobs faster — ideal for large bulk batches and routine maintenance.

Cost-Effective

Lower cost than NABL — right for utility vacuum gauges and non-critical vacuum systems.

Onsite or In-Lab

Bourdon vacuum gauges calibrated onsite; Pirani/capacitance gauges in-lab. Gujarat-wide.

— AREAS WE SERVICE —

Serving All of Gujarat

Onsite vacuum gauge calibration across all Gujarat with portable vacuum references.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL vacuum gauge certificate issued by Prism has been accepted by ISO, IATF, GMP, IBR, PESO, and GPCB auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours. Same-day for urgent plant shutdowns.
Onsite, No Downtime
Portable vacuum references to your plant. No instrument removal, no production loss.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Vacuum Gauge Calibration Quote

Tell us the gauge type, range, quantity, and make. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.