NABL-accredited calibration for RTD calibrators, decade resistance boxes, and PT100/PT1000 simulators. 4-terminal Kelvin bridge method per IEC 60751.

±0.05 Ω

Accuracy

0.1 Ω – 10 kΩ

Range

IEC 60751

Standard

IEC 60751

Platinum RTD Standard

RTD calibrator resistance decade box calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IEC 607514-Terminal MethodNPL TraceablePT100 / PT1000Decade Resistance BoxPharma AcceptedResistance BridgeAll GujaratNABL CC-2480IEC 607514-Terminal MethodNPL TraceablePT100 / PT1000Decade Resistance BoxPharma AcceptedResistance BridgeAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS RTD CALIBRATOR CALIBRATION —

What Is RTD Calibrator Calibration & Why Does It Matter?

Think of a quality lab that relies on a rtd calibrator for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

RTD Calibrator calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

RTD Calibrators & Resistance Standards We Calibrate

Decade Box / Simulator / Reference Resistor · All Makes · IEC 60751 · NABL accredited

01

Portable RTD Calibrator

Portable RTD calibrators for field calibration of RTD sensors and transmitters.

-200°C to 600°CAcc: ±0.05°CIEC 60751
02

Thermocouple Calibrator

Thermocouple calibrators for sourcing and measuring TC signals in the field.

-200°C to 1820°CAcc: ±0.05°CIEC 60584
03

HART Temperature Calibrator

HART temperature calibrators for configuring and calibrating HART transmitters.

-200°C to 850°CAcc: ±0.05°CIEC 61298
04

Reference Thermometer (SPRT/PRT)

SPRT/PRT reference thermometers for primary and secondary temperature reference.

-200°C to 660°CAcc: ±0.001°CIEC 60751
05

Handheld Temperature Calibrator

Handheld temperature calibrators combining TC/RTD source and measure functions.

-200°C to 1372°CAcc: ±0.05°CIEC 60584
06

Temperature Source & Measure Calibrator

Combined temperature source and measure calibrators for complete temperature calibration.

-200°C to 1372°CAcc: ±0.05°CIEC 60751

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Configuration Check

RTD calibrator/decade box received. Output resistance range, excitation current, and interface type documented.

02

4-Terminal Resistance Measurement

Calibrated 4-terminal resistance standard connected. Calibrator output measured via precision Kelvin-type resistance bridge.

03

5-Point Resistance Calibration

Calibrator set to 5 resistance values spanning its range (representing -200°C, 0°C, 100°C, 200°C, 600°C for PT100). Deviation at each point measured.

04

Linearity & Resolution Verification

Linearity and resolution of decade resistance box or simulator verified. Smallest step resolution documented.

05

Uncertainty Calculation

Expanded uncertainty (k=2) calculated per GUM framework. Temperature-equivalent uncertainty in °C provided for PT100 interpretation.

06

NABL Certificate Issue

NABL CC-2480 certificate with resistance values, deviations, temperature equivalents, uncertainty (k=2), IEC 60751 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IEC 60751

Platinum Resistance Thermometers

ITS-90

International Temperature Scale

BIPM / NPL

Primary Resistance Traceability

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. RTD calibrator and resistance standard certificates accepted by NABL-accredited labs, pharma validation bodies, ISO 9001, and all QMS audit bodies.

— NON-NABL CALIBRATION —

Non-NABL RTD Calibrator Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

In-lab calibration of RTD calibrators and decade boxes with NABL-traceable reference standards.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL resistance calibration certificate from Prism has been accepted by NABL labs, pharma validation bodies, and QMS auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. NABL-accredited calibration labs and pharma auditors accept our certificates.
Fast Turnaround
RTD calibrators typically calibrated in 1 business day — ideal for lab downtime minimisation.
Courier Pick-up Gujarat-Wide
Insured courier pick-up and delivery for RTD calibrators from any Gujarat location.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified temperature & resistance specialists
1-Day Turnaround
RTD calibrators calibrated in 1 business day
Zero Rejections
Every certificate pharma & NABL accepted
All Gujarat
Courier pick-up & delivery statewide
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of resistance metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free RTD Calibrator Calibration Quote

Tell us the make/model, resistance range, and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.