NABL-accredited calibration for chart recorders, paperless recorders, and temperature data loggers. Multi-channel calibration per IEC 61298. Pharma, food, and cold chain accepted.
±0.1°C
Accuracy
-200–1600°C
Range
IEC 61298
Standard
IEC 61298
Process Instruments Standard

NABL Accredited
CC-2480
— WHAT IS TEMPERATURE RECORDER CALIBRATION —
Think of a quality lab that relies on a temperature recorder for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.
Temperature Recorder calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.
Compare readings against a NABL-traceable reference standard across the full measurement range.
Adjust or document deviations so your instrument reads within accepted tolerance.
Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.
— INSTRUMENTS COVERED —
Chart Recorder / Paperless Recorder / Data Logger / Validation Logger · All Makes · IEC 61298 · NABL accredited
Strip chart recorders for continuous paper-based temperature recording.
Circular chart recorders for 24-hour cycle temperature documentation.
Paperless digital recorders with LCD display and electronic data storage.
Multi-channel data recorders for simultaneous recording of multiple temperature points.
Electronic temperature data loggers for unattended long-term monitoring.
Combined humidity and temperature loggers for environmental monitoring.
— OUR PROCESS —
Recorder received. Number of channels, input type (TC/RTD), and range documented. Chart or memory medium examined.
Certified TC or RTD simulator connected to each input channel. Reference bath prepared at calibration setpoints.
Each active channel calibrated at 5 temperature setpoints. Recorded values compared with reference. Ascending readings documented.
For data loggers: internal clock compared with GPS/NTP reference. Time accuracy documented for traceability of logged records.
Error at each channel/setpoint calculated. Expanded uncertainty (k=2) documented per GUM. Certificate lists all channels.
NABL CC-2480 multi-channel certificate with per-channel calibration data, uncertainty, IEC 61298 traceability.
— STANDARDS & COMPLIANCE —
IEC 61298
Process Control Instruments
21 CFR Part 11
FDA Electronic Records
GAMP 5
Pharma Validation Guidance
ISO/IEC 17025
NABL Accreditation Standard
Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Temperature recorder and data logger certificates accepted by pharma validation, WHO-cGMP, USFDA, FSSAI, and all ISO 9001 audit bodies.
— NON-NABL CALIBRATION —
For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.
All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.
Without full NABL documentation, instruments return faster — ideal for urgent production schedules.
Non-NABL calibration costs less — practical for large batches or routine periodic checks.
Available at your facility or at our Vatva lab — same quality, more flexibility.
— AREAS WE SERVICE —
Courier pick-up for recorders and loggers. All GIDC zones. Fast digital certificate delivery.
Why Choose Prism
Since 2004, every NABL recorder certificate from Prism has been accepted by pharma, food, and process industry auditors — no rejections.
— FAQ —
Get In Touch
Share the make/model, channel count, and input type. We respond within 2 business hours.
— FROM OUR BLOG —
Temperature data loggers are the backbone of cold chain monitoring and stability chamber validation. NABL-certified calibration ensures their temperature records are accurate and defensible in regulatory audits.
Read MoreThermocouples are the most widely used temperature sensors in industrial furnaces, kilns, and process plants. Proper NABL calibration ensures accuracy across the full temperature range.
Read MoreTemperature is the most measured parameter in Gujarat's industries. Prism's NABL-accredited temperature calibration laboratory in Ahmedabad covers -200°C to +1600°C with highest accuracy.
Read MoreNABL Accreditation Disclaimer
Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.