Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Temperature
Transmitter
Calibration

NABL-accredited calibration for 4–20 mA, HART, Profibus, and wireless temperature transmitters. Input accuracy, output linearity, and span verification per IEC 61298.

±0.1%

Accuracy

-200–1600°C

Range

IEC 61298

Standard

IEC 61298

Process Transmitter Standard

Temperature transmitter calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IEC 612984–20 mA OutputHART Protocol-200°C to 1600°CIn-Situ CalibrationPharma AcceptedOnsite GujaratAll BrandsNABL CC-2480IEC 612984–20 mA OutputHART Protocol-200°C to 1600°CIn-Situ CalibrationPharma AcceptedOnsite GujaratAll Brands
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS TEMPERATURE TRANSMITTER CALIBRATION —

What Is Temperature Transmitter Calibration & Why Does It Matter?

Think of a quality lab that relies on a temperature transmitter for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Temperature Transmitter calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Temperature Transmitters We Calibrate

4–20 mA / HART / Profibus / WirelessHART · All Brands · IEC 61298 · NABL accredited

01

4–20 mA Temperature Transmitter

Standard 4–20 mA temperature transmitters for process control loops.

-200°C to 850°CAcc: ±0.1% FSIEC 61298
02

HART Temperature Transmitter

HART-enabled temperature transmitters for digital communication and remote diagnostics.

-200°C to 850°CAcc: ±0.065% FSIEC 61298
03

RTD Head Transmitter

RTD head-mounted transmitters for compact installation directly on sensor.

-200°C to 600°CAcc: ±0.1% FSIEC 61298
04

DIN Rail Temp Transmitter

DIN rail-mounted temperature transmitters for control panel installation.

-200°C to 850°CAcc: ±0.1% FSIEC 61298
05

Wireless Temperature Transmitter

Wireless temperature transmitters for remote areas without cable infrastructure.

-50°C to 250°CAcc: ±0.2% FSIEC 61298
06

Smart Multivariable Temp Transmitter

Smart multivariable transmitters measuring temperature and additional process variables.

-200°C to 850°CAcc: ±0.1% FSIEC 61298

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Identification

Transmitter model, input type (TC/RTD), output type, HART/Profibus protocol, and range reviewed before calibration.

02

Reference Connection

Certified TC simulator or RTD decade box connected to transmitter input. Precision current meter / HART communicator connected to output loop.

03

5-Point Span Calibration

Certified input applied at 0%, 25%, 50%, 75%, and 100% of calibrated span. Output current measured at each point.

04

Input Error & Output Linearity

Input reading error and output current deviation documented. Non-linearity, hysteresis, and zero/span drift calculated.

05

As-Left Adjustment

Zero and span trimmed if required using HART communicator or trim screws. Post-adjustment readings verified at all 5 points.

06

NABL Certificate Issue

NABL CC-2480 certificate with input/output data, errors, uncertainty (k=2), IEC 61298 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IEC 61298

Process Control Instruments

IEC 60584

Thermocouple Input Verification

IEC 60751

RTD Input Verification

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Temperature transmitter certificates accepted by pharma validation, WHO-cGMP, USFDA, oil & gas, and ISO 9001 audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Temperature Transmitter Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

In-situ HART calibration at your plant or in-lab service for removed transmitters. Same-day pickup and delivery.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL transmitter certificate from Prism has been accepted by pharma, process, and oil & gas audit bodies — no rejections.

NABL CC-2480 — ILAC MRA
Globally recognized. Pharma validation (IQ/OQ/PQ), WHO-cGMP, and USFDA auditors accept our certificates.
In-Situ HART Calibration
Calibrate installed HART transmitters without loop break — minimizes process downtime.
Onsite Plant Service
Engineers equipped with HART communicators and certified simulators — Gujarat-wide.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified instrument specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate pharma & ISO accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of instrumentation metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Transmitter Calibration Quote

Tell us the transmitter brand, model, input type, protocol, quantity, and onsite/in-lab preference. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.