Prism Calibration Centre
Calibration Guide

Torque Wrench Calibration Lab in Gujarat — NABL Certified | Prism

PK
Er. Parthiv Kinariwala · MD, Prism Calibration Centre
16 May 2026 6 min read
NABL CC-2480 ISO/IEC 17025:2017 20+ Years Experience GPCB Authorised ILAC MRA Recognised

Quick Answer

Prism Calibration Centre (NABL CC-2480) at Vatva GIDC, Ahmedabad is the top NABL-certified torque wrench calibration lab in Gujarat. We calibrate click-type, beam-type, digital, and hydraulic torque wrenches per ISO 6789-1:2017, with NABL certificates accepted by IATF 16949, ISO 9001, and aerospace auditors.

Key Takeaways

  • Torque wrench calibration per ISO 6789-1:2017 and ISO 6789-2:2017 standards.
  • Covers click-type, beam-type, dial-type, digital, and hydraulic torque wrenches (1 N·m to 5000 N·m).
  • NABL CC-2480 certificates accepted for IATF 16949, ISO 9001, and aerospace audits.
  • Same-day and urgent calibration available for automotive production lines.
  • Calibration stickers, tags, and calibration history maintained for 3 years.

Types of Torque Tools We Calibrate

  • Click-type torque wrenches (most common in automotive)
  • Beam-type torque wrenches
  • Digital electronic torque wrenches
  • Dial (indicating) torque wrenches
  • Hydraulic torque wrenches (high-torque, oil & gas)
  • Torque screwdrivers (electronics assembly)
  • Torque multipliers
  • Torque transducers and sensors

Calibration Standards for Torque Tools

StandardApplication
ISO 6789-1:2017Torque tool design and quality conformance
ISO 6789-2:2017Calibration and determination of measurement uncertainty
DIN EN ISO 6789European equivalent
ASME B107.28US standard for adjustable torque tools
VDI/VDE 2583Torque screwdriver calibration

How We Calibrate Torque Wrenches

01

Pre-calibration Check

Visual inspection, cleaning, and functional check. Identify range and resolution of the tool.

02

Conditioning Cycles

Per ISO 6789-2, apply 5 conditioning cycles at 100% capacity before taking measurements.

03

Measurement at 5 Points

Measure at 20%, 40%, 60%, 80%, 100% of rated capacity in clockwise and counter-clockwise directions.

04

Uncertainty Calculation

Calculate expanded measurement uncertainty (k=2, 95% confidence level) and compare with manufacturer specs.

05

NABL Certificate Issue

Issue NABL-accredited certificate with as-found / as-left data, uncertainty, and traceability statement.

Serving Gujarat's Automotive Belt

Gujarat is India's automotive capital, home to Tata Motors (Sanand), Suzuki (Manesar), Ford (Sanand), Honda, Hero MotoCorp, and hundreds of Tier 1–2 suppliers across Rajkot, Ahmedabad, and Gandhinagar. All automotive OEMs require IATF 16949 compliance, which mandates torque tool calibration by NABL-accredited labs.

Frequently Asked Questions

How often should torque wrenches be calibrated?

ISO 6789-2:2017 recommends calibration every 12 months or after 5,000 operations, whichever comes first. Automotive plants with high-volume production often calibrate every 6 months.

What is the torque calibration range at Prism?

Prism calibrates torque tools from 0.1 N·m to 5000 N·m, covering hand tools, pneumatic tools, and hydraulic torque wrenches.

Is Prism's torque calibration accepted for IATF 16949 audits?

Yes. Prism's NABL CC-2480 certificates are accepted by all IATF 16949, ISO 9001, and aerospace auditors as they meet ISO/IEC 17025:2017 requirements.

Can Prism calibrate torque wrenches on-site at our Rajkot factory?

Yes. Prism offers on-site torque wrench calibration services across Gujarat including Rajkot, Surat, Vadodara, and Ahmedabad.

What information is on a Prism NABL torque calibration certificate?

The certificate includes: equipment details (make, model, serial, range), calibration date and due date, measurement results at 5 points, expanded uncertainty, traceability statement, NABL accreditation logo, and authorized signatory.

Written by

PK

Er. Parthiv Kinariwala

Managing Director · Prism Calibration Centre · NABL CC-2480 · Ahmedabad

Er. Parthiv Kinariwala founded Prism Calibration Centre in 2004 and has over 20 years of hands-on experience in calibration engineering, NABL accreditation, and industrial compliance. His team performs 10,000+ calibrations annually from the Vatva GIDC laboratory, serving 5000+ industries across Gujarat.

NABL CC-2480 SignatoryISO/IEC 17025 ExpertGPCB AuthorisedBEE Energy AuditorILAC MRA Member

Prism Calibration Centre — Vatva GIDC, Ahmedabad

Prism Calibration Centre

F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Near Jasoda Nagar Cross Road, Ahmedabad382445, Gujarat, India

Phone: +91 98245 26444

Email: info@prismcalibration.com

NABL: CC-2480 · ISO/IEC 17025:2017

Hours: Mon–Sat, 9:00 AM – 7:00 PM