Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Caliper
Calibration
Services

NABL-accredited calibration for all caliper types — Vernier, Digital, Depth, Step, Inside & Outside. ISO 13225 traceable, accepted by ISO 9001, IATF 16949, and all quality auditors.

±0.003 mm

Uncertainty

0–600 mm

Range

ISO 13225

Standard

ISO 13225

Caliper Standard

Caliper calibration NABL Gujarat

NABL Accredited

CC-2480

NABL · CC-2480ISO 13225NPL TraceableILAC MRA RecognizedISO 9001:2015IATF 16949±0.003 mm UncertaintyOnsite Gujarat6 Caliper TypesNABL · CC-2480ISO 13225NPL TraceableILAC MRA RecognizedISO 9001:2015IATF 16949±0.003 mm UncertaintyOnsite Gujarat6 Caliper Types
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS CALIPER CALIBRATION —

What Is Caliper Calibration & Why Does It Matter?

Think of a tailor who uses a measuring tape that stretches over time — the clothes they stitch will never fit right. A caliper works the same way. If its jaw is worn or its zero has drifted, every measurement your quality team makes is wrong — and so are the parts you produce.

Caliper calibration means checking your caliper against certified gauge blocks traceable to NPL, finding how much it reads high or low, correcting it, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, BIS, and every quality auditor.

Check

We measure against NPL-traceable gauge blocks at 5+ points and record all errors (As-Found).

Correct

We adjust the zero, check jaw parallelism, and issue a correction table if needed.

Certify

NABL CC-2480 certificate with as-found/as-left data — accepted by ISO 9001 & IATF.

— INSTRUMENTS COVERED —

Calipers We Calibrate

All 6 caliper types · All makes (Mitutoyo, Baker, Insize, Starrett) · NABL accredited

01

Vernier Caliper (Inside / Outside)

Vernier calipers for inside, outside, depth, and step measurements.

0–300 mmRes: ±0.02 mmISO 13225
02

Digital Caliper

Digital calipers with electronic display and inch/mm conversion.

0–300 mmRes: ±0.01 mmISO 13225
03

Depth Caliper

Depth calipers for measuring hole depth and slot depth.

0–200 mmRes: ±0.02 mmISO 13225
04

Step / Offset Caliper

Step and offset calipers for measuring heights and steps.

0–200 mmRes: ±0.02 mmISO 13225
05

Inside Caliper

Inside calipers for measuring internal diameters and widths.

10–200 mmRes: ±0.1 mmISO 13225
06

Outside Caliper

Outside calipers for measuring external dimensions and diameters.

0–200 mmRes: ±0.1 mmISO 13225

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Tagging

Caliper received, tagged, incoming condition documented — jaw condition, scale legibility, depth rod.

02

Zero & Cleaning

Jaws cleaned, zero error noted (as-found). Sliding action and depth rod movement checked and recorded.

03

As-Found Measurement

Measured against NPL-traceable gauge blocks at 5+ points. All deviations recorded.

04

Adjustment

Zero adjustment performed. Correction table issued for fixed-reading instruments.

05

As-Left Verification

Post-adjustment readings verified at all calibration points. Uncertainty calculated per ISO/IEC 17025.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty (k=2), ISO 13225 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

Every caliper calibration follows documented ISO 13225 and NPL procedures — accepted by ISO 9001, IATF 16949, BIS, FDA, and GPCB auditors.

ISO 13225

Caliper Calibration Standard

ISO/IEC 17025

NABL Accreditation Standard

NPL / NIST

Traceable Reference Standards

IATF 16949

Automotive Quality Standard

ISO 9001:2015

Quality Management System

ASME B89.1.14

Calipers US Standard

IS 3651

BIS Vernier Caliper Standard

ISO 14978

GPS Measuring Instruments

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017, recognized under the ILAC MRA agreement. Our caliper calibration certificates are valid for ISO 9001, IATF 16949, BIS, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Caliper Calibration Also Available

For routine maintenance, bulk calibration, or workshops not needing NABL certification — Prism offers cost-effective non-NABL caliper calibration with the same trained engineers and traceable references.

Internal maintenance & routine checks
Pre-delivery and incoming inspection
Bulk calibration for non-critical calipers
R&D, prototype & workshop environments
Cost-effective for projects without audit requirements

Traceable References

All non-NABL jobs use the same NPL-traceable gauge blocks — only the certificate type differs.

Faster Turnaround

Non-NABL caliper jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and as onsite service across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

NABL-certified engineers travel to your facility with portable gauge block sets — calibrate 50+ calipers per day onsite, zero downtime.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL caliper certificate issued by Prism has been accepted by ISO, IATF, BIS, FDA, and GPCB auditors — no rejections, no rework.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Fast Certificate Delivery
Same-day urgent service available. Certificates delivered digitally within 24 hours.
100% Onsite, No Downtime
Engineers travel to your facility with gauge block sets. No instrument removal.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Caliper Calibration Quote

Tell us how many calipers you need calibrated, the types, and whether you need onsite or in-lab service. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.