Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Dial Gauge
Calibration
Services

NABL-accredited calibration for all dial gauge types — Plunger, Lever, Bore, Thickness & Back-Plunger. ISO 463 traceable, accepted by ISO 9001, IATF 16949.

±0.001 mm

Uncertainty

0–50 mm

Range

ISO 463

Standard

ISO 463

Dial Gauge Standard

Dial gauge calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 463NPL Traceable±0.001 mm UncertaintyISO 9001 AcceptedIATF 169495 Dial Gauge TypesOnsite GujaratNABL CC-2480ISO 463NPL Traceable±0.001 mm UncertaintyISO 9001 AcceptedIATF 169495 Dial Gauge TypesOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS DIAL GAUGE CALIBRATION —

What Is Dial Gauge Calibration & Why Does It Matter?

A dial gauge with a sticky plunger or inaccurate graduations will give wrong runout and flatness readings — leading to acceptance of defective parts. Dial gauge calibration verifies resolution, repeatability, and linearity against NPL standards with an NABL certificate.

Check

Measured against NPL-traceable gauge blocks at multiple points. Zero return and retrace error recorded.

Correct

Bezel zero adjustment, plunger friction check. Correction table issued if needed.

Certify

NABL CC-2480 certificate with as-found/as-left data — accepted by ISO 9001 & IATF.

— INSTRUMENTS COVERED —

Dial Gauges We Calibrate

All 5 dial gauge types · All makes (Mitutoyo, Baker, Insize, Sylvac, Mahr) · NABL accredited

01

Plunger Dial Gauge

Plunger-type dial gauges for vertical displacement and runout measurement.

0–10 mmRes: ±0.01 mmISO 463
02

Lever Type Dial Gauge

Lever-type (test indicator) dial gauges for surface form and runout checking.

0–0.8 mmRes: ±0.001 mmISO 463
03

Bore Dial Gauge

Bore dial gauges for measuring internal diameters with high accuracy.

6–250 mm boreRes: ±0.003 mmISO 463
04

Dial Thickness Gauge

Dial thickness gauges for sheet, film, and flat material thickness measurement.

0–20 mmRes: ±0.01 mmISO 463
05

Back-Plunger Dial Gauge

Back-plunger dial gauges for measuring in confined spaces with side access.

0–10 mmRes: ±0.01 mmISO 463

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Tagging

Dial gauge received, tagged, condition documented — bezel condition, pointer action, plunger travel.

02

Zero & Cleaning

Plunger and contact point cleaned, zero error noted (as-found). Plunger movement and return-to-zero checked.

03

As-Found Measurement

Measured against NPL-traceable gauge blocks at multiple points. All deviations recorded.

04

Adjustment

Bezel zero adjustment performed. Correction table issued for instruments with systematic error.

05

As-Left Verification

Post-adjustment readings verified at all calibration points. Uncertainty calculated per ISO/IEC 17025.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty (k=2), ISO 463 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 463

Dial Gauges (Plunger Type)

JIS B 7503

Dial Gauges (Japanese Std)

IS 3073

Dial Gauges (Indian Standard)

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Our dial gauge calibration certificates are valid for ISO 9001, IATF 16949, BIS, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Dial Gauge Calibration Also Available

For routine maintenance or workshops not needing NABL certification — cost-effective non-NABL dial gauge calibration with the same engineers and traceable references.

Internal maintenance & routine checks
Pre-delivery and incoming inspection
Bulk calibration for non-critical dial gauges
R&D, prototype & workshop environments
Cost-effective for projects without audit requirements

Traceable References

All non-NABL jobs use NPL-traceable gauge blocks — only the certificate type differs.

Faster Turnaround

Non-NABL dial gauge jobs completed faster — ideal for urgent maintenance or bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and onsite across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

NABL-certified engineers travel to your facility with portable gauge block sets — calibrate 50+ dial gauges per day onsite, zero downtime.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL dial gauge certificate issued by Prism has been accepted by ISO, IATF, BIS, FDA, and GPCB auditors — no rejections, no rework.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Fast Certificate Delivery
Same-day urgent service available. Certificates delivered digitally within 24 hours.
100% Onsite, No Downtime
Engineers travel to your facility with gauge block sets. No instrument removal.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Dial Gauge Calibration Quote

Tell us how many dial gauges you need calibrated, the types and ranges, and whether you need onsite or in-lab service. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.