Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Height & Snap Gauge
Calibration
Services

NABL-accredited calibration for Height Gauges (Analog & Digital), Snap Gauges (Fixed & Adjustable), and Caliper Checkers. ISO 13225 traceable, accepted by ISO 9001, IATF 16949.

±0.003 mm

Uncertainty

0–1000 mm

Range

ISO 13225

Standard

ISO 13225

Height Gauge Standard

Height gauge calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 13225ISO 1938NPL Traceable±0.003 mm UncertaintyISO 9001 AcceptedIATF 169495 Gauge TypesOnsite GujaratNABL CC-2480ISO 13225ISO 1938NPL Traceable±0.003 mm UncertaintyISO 9001 AcceptedIATF 169495 Gauge TypesOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS HEIGHT GAUGE CALIBRATION —

What Is Height Gauge Calibration & Why Does It Matter?

A height gauge with a drifted zero datum will give wrong vertical dimensions on every machined part it inspects. Height gauge calibration verifies linearity, beam squareness, and zero datum against NPL-traceable gauge blocks on a Grade-A surface plate.

Check

Measured against NPL-traceable gauge blocks on Grade-A surface plate at 5+ points. As-found data recorded.

Correct

Zero datum reset, beam squareness checked. Snap gauge GO/NO-GO dimensions verified against masters.

Certify

NABL CC-2480 certificate with as-found/as-left data — accepted by ISO 9001 & IATF.

— INSTRUMENTS COVERED —

Height & Snap Gauges We Calibrate

All 5 gauge types · All makes (Mitutoyo, Baker, Insize, Starrett) · NABL accredited

01

Height Gauge (Analog)

Analog vernier height gauges for scribing and height measurement on surface plates.

0–600 mmRes: ±0.02 mmISO 13225
02

Height Gauge (Digital)

Digital height gauges with electronic display for precision height measurement.

0–1000 mmRes: ±0.01 mmISO 13225
03

Snap Gauge (Fixed)

Fixed snap gauges (Go/No-Go) for rapid diameter acceptance testing.

3–200 mmRes: ±0.005 mmISO 1938
04

Snap Gauge (Adjustable)

Adjustable snap gauges for flexible diameter tolerance checking.

3–200 mmRes: ±0.005 mmISO 1938
05

Caliper Checker

Caliper checkers for verification of caliper calibration and accuracy.

0–300 mmRes: ±0.01 mmISO 13225

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Tagging

Gauge received, tagged, condition documented — beam condition, scribing needle, digital readout.

02

Zero & Surface Check

Surface plate datum verified, zero error noted (as-found). Beam squareness and column movement checked.

03

As-Found Measurement

Measured against NPL-traceable gauge blocks on Grade-A surface plate at 5+ points. All deviations recorded.

04

Adjustment

Zero adjustment performed. Beam straightness corrected where applicable. Correction table issued.

05

As-Left Verification

Post-adjustment readings verified at all calibration points. Uncertainty calculated per ISO/IEC 17025.

06

NABL Certificate

NABL CC-2480 certificate with as-found/as-left data, uncertainty (k=2), ISO 13225 / ISO 1938 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 13225

Calipers & Height Gauges

ISO 1938

Limit Gauges (Snap Gauges)

IS 3651

Height Gauge (Indian Standard)

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Our height gauge and snap gauge calibration certificates are valid for ISO 9001, IATF 16949, BIS, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Height & Snap Gauge Calibration Also Available

For routine maintenance or workshops not needing NABL certification — cost-effective non-NABL calibration with the same engineers and traceable references.

Internal maintenance & routine checks
Pre-delivery and incoming inspection
Bulk calibration for non-critical gauges
R&D, prototype & workshop environments
Cost-effective for projects without audit requirements

Traceable References

All non-NABL jobs use NPL-traceable gauge blocks — only the certificate type differs.

Faster Turnaround

Non-NABL jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Available at our Ahmedabad lab and onsite across Gujarat — same team, same quality.

— AREAS WE SERVICE —

Serving All of Gujarat

NABL-certified engineers travel to your facility with portable gauge block sets and surface plates — zero downtime.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL height gauge and snap gauge certificate issued by Prism has been accepted by ISO, IATF, BIS, FDA, and GPCB auditors — no rejections, no rework.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Fast Certificate Delivery
Same-day urgent service available. Certificates delivered digitally within 24 hours.
100% Onsite, No Downtime
Engineers travel to your facility with gauge block sets. No instrument removal.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Height & Snap Gauge Calibration Quote

Tell us the gauge types and quantities needed. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.