Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Measuring Tape &
Misc Instruments
Calibration

NABL-accredited calibration for Steel Measuring Tapes, Steel Scales, Radius Gauges, and Wire Gauges. IS 1270 / OIML R 35 traceable. Accepted by ISO 9001, IATF 16949 auditors.

±0.5 mm

Uncertainty

2m–50m

Tape Range

IS 1270

Standard

IS 1270 / OIML R 35

Measuring Tape Standards

Measuring tape calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480IS 1270OIML R 35IS 4026NPL Traceable±0.5 mmISO 9001 AcceptedSteel Tapes 2m–50mOnsite GujaratNABL CC-2480IS 1270OIML R 35IS 4026NPL Traceable±0.5 mmISO 9001 AcceptedSteel Tapes 2m–50mOnsite Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS MEASURING TAPE CALIBRATION —

What Is Measuring Tape Calibration & Why Does It Matter?

A stretched or shrunk steel tape gives wrong dimensions on every measurement — leading to layout errors, construction defects, and rejected parts. Measuring tape calibration verifies graduation accuracy across the full tape length against NPL-traceable references per IS 1270.

Measure

Tape measured at 10+ points across full length against NPL-traceable references in controlled environment.

Assess

MPE per IS 1270 / OIML R 35 assessed. Hook condition, graduation clarity verified.

Certify

NABL CC-2480 certificate with errors at all measured points — accepted by ISO 9001 & legal metrology.

— INSTRUMENTS COVERED —

Tapes & Misc Instruments We Calibrate

Steel Tapes · Steel Scales · Radius Gauges · Wire Gauges · IS 1270 / OIML R 35 · NABL accredited

01

Measuring Tape (Steel, 2m–50m)

Steel measuring tapes for general linear measurement from 2 m to 50 m.

2–50 mAcc: ±1 mm / 10 mIS 1270
02

Steel Scale / Rule

Steel scales and rules for short-range linear and depth measurement.

150–600 mmAcc: ±0.1 mmIS 1270
03

Radius Gauge

Radius gauges for measuring concave and convex radii on machined parts.

R1–R25 mmAcc: ±0.1 mmISO 3611
04

Wire Gauge

Wire gauges for measuring wire diameter and sheet metal thickness.

0.1–10 mmAcc: ±0.01 mmISO 3611

— OUR PROCESS —

Calibration Process — Step by Step

01

Intake & Tagging

Instrument received, tagged, type and range documented. Tape rewind, blade condition, and hook condition noted.

02

Visual Inspection

Graduation clarity, hook condition, blade kinks, and surface rust checked. As-found condition recorded.

03

As-Found Measurement

Tape or scale measured at 10+ points against NPL-traceable length references in controlled environment.

04

Error Assessment

Maximum permissible error (MPE) per IS 1270 / OIML R 35 assessed. Errors plotted against scale length.

05

As-Left Verification

Final readings confirmed and recorded. Pass/fail determined. Correction table prepared if required.

06

NABL Certificate

NABL CC-2480 certificate with as-found data, errors at measured points, uncertainty (k=2), IS 1270 / OIML R 35 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

IS 1270

Steel Measuring Tapes (Indian Standard)

OIML R 35

Measuring Tapes (International Standard)

IS 4026

Radius Gauges (Indian Standard)

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Measuring tape and misc instrument certificates are valid for ISO 9001, IATF 16949, legal metrology, and all audit purposes.

— NON-NABL CALIBRATION —

Non-NABL Tape Calibration Also Available

For routine maintenance or workshops not needing NABL certification — cost-effective non-NABL measuring tape calibration with the same engineers and traceable references.

Internal maintenance & routine checks
Pre-delivery and incoming inspection
Bulk calibration for construction tapes
R&D, prototype & workshop environments
Cost-effective for projects without audit requirements

Traceable References

All non-NABL jobs use NPL-traceable length standards — only the certificate type differs.

Faster Turnaround

Non-NABL tape jobs completed faster — ideal for urgent maintenance or large bulk batches.

Cost-Effective

Priced lower than NABL — right choice for internal checks and non-audit use cases.

Onsite or In-Lab

Short tapes onsite; long tapes (10m+) at our controlled Ahmedabad lab.

— AREAS WE SERVICE —

Serving All of Gujarat

Onsite calibration for short tapes and scales. Collection and delivery for long tapes. All Gujarat GIDC zones covered.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL measuring tape and misc instrument certificate issued by Prism has been accepted by ISO, IATF, BIS, FDA, and GPCB auditors.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by FDA, GPCB, ISO auditors internationally.
Fast Certificate Delivery
Same-day urgent service available. Certificates delivered digitally within 24 hours.
Onsite + Collection Service
Engineers onsite for short instruments. Collection and delivery for long tapes.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate ISO & IATF accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Tape & Misc Instrument Calibration Quote

Tell us the instrument type, range, and quantity. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.