Pipette
Calibration
NABL Accredited

NABL-accredited calibration for volumetric, graduated, and transfer glass pipettes. ISO 8655 gravimetric method. 1 µL – 100 mL. Pharma GMP compliant.

1 µL – 100 mL

Range

ISO 8655 Gravimetric

Method

ISO 648 / ISO 8655

Standard

ISO 8655 / ISO 648

Gravimetric Pipette Calibration

Pipette calibration NABL gravimetric ISO 8655 Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 8655ISO 648ISO 8351 µL–100 mLGravimetric MethodPharma GMPISO 15189All GujaratNABL CC-2480ISO 8655ISO 648ISO 8351 µL–100 mLGravimetric MethodPharma GMPISO 15189All Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS PIPETTE CALIBRATION —

What Is Pipette Calibration & Why Does It Matter?

Think of a quality lab that relies on a pipette for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Pipette calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Pipettes We Calibrate

Volumetric / Transfer / Graduated / Serological / Micro · ISO 8655 Gravimetric · NABL CC-2480

01

Graduated Pipette

Graduated pipettes with multiple volume markings for flexible liquid transfer.

0.1–25 mLU = ±0.1 mLISO 835
02

Volumetric Pipette

Volumetric pipettes with single calibrated volume marking for accurate delivery.

1–100 mLU = ±0.02 mLISO 648
03

Pasteur Pipette

Pasteur glass pipettes for transferring small volumes in laboratory work.

1–3 mLU = ±0.05 mLISO 7550
04

Transfer Pipette

Transfer pipettes for liquid transfer without precision volume requirement.

1–10 mLU = ±0.5 mLISO 7550
05

Serological Pipette

Serological pipettes with graduation for cell culture and clinical use.

1–50 mLU = ±0.1 mLISO 7550
06

Bulb Pipette

Bulb pipettes with enlarged midSection for accurate fixed-volume measurement.

1–100 mLU = ±0.02 mLISO 648

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Temperature Stabilisation

Pipette and ultra-pure water (ISO 3696 Grade 1) stabilised at 20 ± 0.5°C for at least 30 minutes in temperature-controlled calibration room.

02

Visual Inspection

Pipette inspected for cracks, chips at tip, contamination, and scale legibility. Any defects recorded. Tip diameter and seating checked.

03

Gravimetric Calibration

Water dispensed into tared weighing vessel on NABL-calibrated analytical balance. Dispensed mass converted to volume using Z-factor (density and surface tension at calibration temperature).

04

5 Repeat Measurements at Each Volume

At least 5 repeat dispenses at each nominated volume setpoint. Mean volume, standard deviation, and systematic error (bias) computed per ISO 8655 / ISO 4787.

05

Error vs Tolerance Check

Mean error and repeatability (coefficient of variation, CV%) compared to ISO 648 / ISO 835 / ISO 8655 tolerance limits for the stated class.

06

NABL Certificate Issue

NABL CC-2480 certificate reporting dispensed volume, bias, repeatability (CV%), expanded uncertainty (k=2), calibration temperature, and ISO 8655 / ISO 648 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 8655

Piston-Operated & Glass Pipettes

ISO 648

Class A / B Volumetric Pipettes

ISO 835

Graduated (Transfer) Pipettes

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Pipette calibration certificates accepted by pharma GMP (21 CFR Part 211), ISO 15189, ISO 9001, and food & dairy industry auditors.

— NON-NABL CALIBRATION —

Non-NABL Pipette Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Lab calibration. 1-day turnaround for most pipette sets.

10 Major Cities · All GIDC Zones
Request Quote
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL pipette certificate from Prism has been accepted by pharma GMP, ISO 15189, and ISO 9001 auditors — no rejections.

NABL CC-2480 — ILAC MRA
Accepted by pharma GMP, ISO 15189, ISO 9001 auditors globally.
1-Day Turnaround
Pipette sets calibrated and certified in 1 business day.
All Gujarat Coverage
Collection and delivery across Gujarat.
Triple Govt. Authorization
NABL + GPCB + BEE — rare triple accreditation in Gujarat.
70+ Engineers
NABL-certified volumetric specialists
1-Day Turnaround
Fast digital certificate delivery
Zero Rejections
Every certificate ISO/GMP accepted
All Gujarat
Every GIDC zone covered
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of volumetric metrology

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Pipette Calibration Quote

Share the type, volume, class, and quantity. We respond within 2 business hours.