Prism Calibration Centre
NABL Accredited · CC-2480 · Est. 2004

Torque Transmission
Tool Calibration
Services

NABL-accredited calibration for torque wrenches (transfer), nutrunners, slip clutches, and screwdrivers from 0.01 N·m to 50,000 N·m. ISO 6789 / ISO 5393 traceable. IATF 16949 accepted.

±3% / ±4%

Accuracy Class

0.01–50000 N·m

Range

ISO 6789

Standard

ISO 6789

Torque Tool Calibration Standard

Torque transmission tool calibration NABL Gujarat

NABL Accredited

CC-2480

NABL CC-2480ISO 6789ISO 5393NPL Traceable0.01–50000 N·mClick & Slip & NutrunnerIATF 16949 AcceptedShop Floor OnsiteAll GujaratNABL CC-2480ISO 6789ISO 5393NPL Traceable0.01–50000 N·mClick & Slip & NutrunnerIATF 16949 AcceptedShop Floor OnsiteAll Gujarat
0+
Industries Served
Across Gujarat since 2004
0+
Instruments Calibrated
With NABL traceability
0+
Expert Engineers
Field & lab technicians
0%
Repeat Client Rate
Client satisfaction & trust

— WHAT IS TORQUE TRANSMISSION CALIBRATION —

What Is Torque Transmission Calibration & Why Does It Matter?

Think of a quality lab that relies on a torque transmission for daily measurements. If it has drifted even slightly from its true value, every reading becomes unreliable — leading to defective products, failed audits, or safety risks. Regular calibration is the only way to confirm your instrument is telling the truth.

Torque Transmission calibration means comparing its readings against a NABL-traceable certified reference standard at multiple test points, recording the deviations, adjusting where possible, and issuing an NABL certificate — accepted by ISO 9001, IATF 16949, and all quality auditors.

Check

Compare readings against a NABL-traceable reference standard across the full measurement range.

Correct

Adjust or document deviations so your instrument reads within accepted tolerance.

Certify

Issue a NABL-accredited certificate (CC-2480) with full traceability documentation.

— INSTRUMENTS COVERED —

Torque Transmission Tools We Calibrate

Click Wrench / Nutrunner / Slip Clutch / Screwdriver · All makes (Norbar, Atlas Copco, Gedore) · ISO 6789 · NABL accredited

01

Torque Multiplier

Torque multipliers for amplifying input torque for high-torque fastening.

Up to 30,000 NmAcc: ±3% FSISO 6789
02

Torque Limiter / Coupler

Torque limiters and couplers for protecting machinery from overload.

0.1–10,000 NmAcc: ±1% FSISO 6789
03

Drive Shaft Torque Sensor

Drive shaft torque sensors for measuring torque in power transmission shafts.

10–50,000 NmAcc: ±0.2% FSISO 6789
04

Gearbox Torque Tester

Gearbox torque testers for verifying torque transmission efficiency.

10–100,000 NmAcc: ±0.5% FSISO 6789

— OUR PROCESS —

Calibration Process — Step by Step

01

Receipt & Inspection

Torque transmission device received and tagged. Drive mechanism, clutch, ratchet, or coupling inspected. Visual condition documented.

02

Pre-Load Conditioning

For wrenches and screwdrivers: 5 pre-load cycles at target torque before formal measurement. For nutrunners: 10 tool actuations at set torque.

03

3 or 5 Measurement Series

Three measurements at each test torque (ISO 6789 minimum) or five (for transfer standard classification). Data captured via calibrated transducer and analyser.

04

Clockwise & Counter-Clockwise

CW and CCW directions verified where applicable. Symmetry of the torque transmission mechanism documented.

05

Accuracy Classification

Mean, standard deviation, and relative error calculated. ISO 6789 accuracy class determined (±3%, ±4%, or ±6%).

06

NABL Certificate Issue

NABL CC-2480 certificate with torque values, accuracy class, uncertainty (k=2), ISO 6789 / ISO 5393 traceability.

— STANDARDS & COMPLIANCE —

Backed by International Standards

ISO 6789

Assembly Torque Tools — Calibration

ISO 5393

Rotary Tools — Test Methods

ASME B107.300

Torque Instruments Standard

ISO/IEC 17025

NABL Accreditation Standard

NABL Accreditation — CC-2480

Prism holds NABL CC-2480 under ISO/IEC 17025:2017. Torque tool certificates accepted by IATF 16949, ISO 9001, and all automotive, aerospace, and heavy engineering assembly audit bodies.

— NON-NABL CALIBRATION —

Non-NABL Torque Transmission Calibration Also Available

For routine maintenance, bulk calibration, or internal QC checks where a full NABL certificate is not mandatory — Prism offers cost-effective non-NABL calibration using the same NABL-traceable reference standards and trained engineers.

  • All measurements traceable to NABL-accredited references
  • Same Prism engineers, same lab equipment
  • Calibration report with readings and deviations provided
  • Ideal for internal QA, maintenance, or high-volume batches
  • Upgrade to full NABL certificate at any time

Traceable References

All non-NABL work uses NABL-certified reference standards — readings are still reliable and defensible.

Faster Turnaround

Without full NABL documentation, instruments return faster — ideal for urgent production schedules.

Cost-Effective

Non-NABL calibration costs less — practical for large batches or routine periodic checks.

Onsite or In-Lab

Available at your facility or at our Vatva lab — same quality, more flexibility.

— AREAS WE SERVICE —

Serving All of Gujarat

Engineers bring portable torque analysers directly to your production floor. Onsite calibration for shop-floor torque tools across Gujarat.

10 Major Cities · All GIDC Zones
Request Onsite Visit
Ahmedabad
Vadodara
Bharuch
Dahej
Ankleshwar
Surat
Rajkot
Gandhinagar
Nadiad
Anand

Why Choose Prism

Two Decades of Precision.
Zero Audit Failures.

Since 2004, every NABL torque certificate issued by Prism has been accepted by IATF 16949, ISO 9001, and automotive assembly audit bodies — no rejections.

NABL CC-2480 — ILAC MRA
Accepted in 100+ countries. Recognized by IATF, ISO, and ASME audit bodies globally.
Same-Day Urgent Service
Certificates delivered digitally within 24 hours for urgent assembly line audit needs.
Onsite Production Floor Service
Engineers calibrate nutrunners and shop-floor tools at your assembly line across Gujarat.
Triple Govt. Authorization
NABL + GPCB + BEE — one of very few Gujarat labs holding all three simultaneously.
70+ Engineers
NABL-certified field & lab specialists
Same-Day Service
Urgent certificates when you need them
Zero Rejections
Every certificate IATF & ISO accepted
All Gujarat
Every GIDC zone covered onsite
ILAC MRA
Globally recognized, 100+ countries
Since 2004
20+ years of unbroken track record

— FAQ —

Frequently Asked Questions

Get In Touch

Request a Free Torque Tool Calibration Quote

Tell us the tool type, range (N·m), make/model, quantity, and if you need onsite or in-lab service. We respond within 2 business hours.

Address
F-101, Rudraksh Complex 2, Phase 3, GIDC Vatva, Ahmedabad 382445

Send an Enquiry

— FROM OUR BLOG —

Related Articles & Guides

NABL Accreditation Disclaimer

Calibration services are provided under NABL Certificate CC-2480 in strict accordance with our officially approved scope of accreditation (ISO/IEC 17025:2017). Parameters or onsite conditions falling outside our active NABL scope are processed with standard metrological traceability to NPL/BIPM national standards.